Home ] Up ] GSE Parts Department ] Feedback ] HOBART GROUND POWER ] Hobart Ground Power 400Hz & DC Data Sheets ] 400Hz POWER & DISTRIBUTION ] 400 Hz & DC LOAD BANKS ] HOBART PARTS QUOTE ] COLEMAN ENGINEERING ] HOBART GPU QUOTE ] Trilectron Ground Equipment ] Hangar 400Hz & DC Power Systems ] Aircraft Air Conditioners ] Hobart GPU Manuals ] AGE Corp Military Products ● Freeport ● NY ]


Home
Up
GSE Parts Department
Feedback
HOBART GROUND POWER
Hobart Ground Power 400Hz & DC Data Sheets
400Hz POWER & DISTRIBUTION
400 Hz & DC LOAD BANKS
HOBART PARTS QUOTE
COLEMAN ENGINEERING
HOBART GPU QUOTE
Trilectron Ground Equipment
Hangar 400Hz & DC Power Systems
Aircraft Air Conditioners
Hobart GPU Manuals
AGE Corp Military Products ● Freeport ● NY
 

HOBART DATA SHEETS

GET A QUOTE

Terms & Conditions of sale

     

SPECIFICATIONS

Inputs

Model

Amperage

Hertz

Voltage

45SX200  55  @460 VAC
 61  @400 VAC    120 @208VAC
45-66 340-530
60SX200 100 @ 460 VAC
118 @ 400VAC
45-66 340-530
90SX200 100 @ 460 VAC
118 @ 400VAC
45-66 340-530
120SX200 134 @ 460 VAC
154 @ 400VAC
45-66 340-530
140SX200 156 @ 460 VAC
180 @ 400VAC
45-66 340-530
160SX200 179@ 460 VAC
205 @ 400VAC
45-66 340-530
180SX200 200 @ 460 VAC
230 @ 400 VAC
45-66 340-530
  • Configuration: 3 wire with grounded service
  • Starting Current: <100% full load
  • Power Factor: >0.98 lagging from 10% to full load

Output

  • Ratings:
  • 45KVA ( 36KW continuous)
  • 60 KVA ( 48KW continuous)
  • 90 KVA ( 72KW continuous)
    115/200 VAC, 3 Ph, 400Hz
  • 120 KVA (96KW continuous)
  • 140 KVA (112KW continuous)
  • 160 KVA (128KW continuous)
  • 180 KVA (144KW continuous)
  • Overloads:
    125% - 10 minutes
    150% - 30 seconds
    200% - 10 seconds
  • Short Circuit Protected
  • NBPT: specifically designed to service present and future aircraft no-break power requirements

Protection

  • Input:
Phase loss
Low/High Input Voltage
  • Output:
Over/Under Voltage per Mil Std 704E  & ARP5015
Over/Under Frequency per Mil Std 704E & ARP5015
Short Circuit - Solid state shutdown of unit without damage to unit
  • Internal:
Door interlock
Cooling loss/Over temperature
Contactor Failure
    Contacts Stuck (Open/Closed)
    Coil Open
Power Supply Voltage
Transistor failure / over current
Lamp test

Environmental

  • Acoustical Noise:
    <
    65dBA @1.5M high, 1M distance
  • Operating Temperature:
    - 40° C to + 52° C (-40° F to +125° F)
  • Non-Operating Temperature:
    -40° C to +60° C (-40° F to +140° F)
  • Ventilation:
    filtered forced air
  • Enclosure:
    NEMA 3R/IEC IP 54

Voltage

  • Voltage Regulation: less than ±1% no load to rated load
  • THD (total harmonic distortion): < 3%
  • IHC (individual harmonic content): <2%
  • DC Content: 100mv maximum
  • Voltage Modulation: <0.5% RMS
  • Phase Displacement: 120 ±1.5 degrees
  • Transient Performance exceeds Mil-Std-704E
  • Output Voltage Adjustment Range: ±15%
  • Phase Voltage Balance (balanced load): <2%
  • Voltage Unbalance (10% unbalanced load on a single phase): < 3 volts
  • Crest Factor: 1.414 ±0.07
  • Line Drop Compensation: Automatic up to 8%

Frequency

  • Frequency Modulation: < ±0.25%
  • Frequency Regulation: ± 0.2 Hz (.05 %)
  • Frequency Drift: ±0.05% at any load

Controls/ Indicators

  • On/Off: each output
  • Output Voltage: each phase (L-N) and avg.
  • Output Current: each phase and avg.
  • Input Power Lamp (green)
  • Output Power Lamp: each output (amber)
  • Fault Lamp (red)
  • EF Interlock Status
  • Circuit Breaker Handle: removes input power
  • Door Interlock
  • Line Drop Compensation Adjust

Weight

Model

Standard

12-Pulse Option

45SX200 1100 lbs.
(500 kg)
1300 lbs.
(591 kg)
60SX200 1100 lbs.
(500 kg)
1300 lbs.
(591 kg)
90SX200 1100 lbs.
(500 kg)
1300 lbs.
(591 kg)
120SX200 1330 lbs.
(603 kg)
1782 lbs.
(808 kg)
140SX200 1330 lbs.
(603 kg)
1782 lbs.
(808 kg)
160SX200 1330 lbs.
(603 kg)
1782 lbs.
(808 kg)
180SX200 1330 lbs.
(603 kg)
1782 lbs.
(808 kg)

Specifications subject to change without notice


 

 

(516) 546-0003            (800) 758-0044

GSE Parts Department ] Feedback ] HOBART GROUND POWER ] Hobart Ground Power 400Hz & DC Data Sheets ] 400Hz POWER & DISTRIBUTION ] 400 Hz & DC LOAD BANKS ] HOBART PARTS QUOTE ] COLEMAN ENGINEERING ] HOBART GPU QUOTE ] Trilectron Ground Equipment ] Hangar 400Hz & DC Power Systems ] Aircraft Air Conditioners ] Hobart GPU Manuals ] AGE Corp Military Products ● Freeport ● NY ]

Send mail to WEBMASTER@AVIATIONGROUNDEQUIP.COM with questions or comments about this web site.
Copyright © 1999 Aviation Ground Equipment Corp.                                   
Last modified: August 03, 2009